en:bop.bas:180

BOP.BAS.180 Use of supplemental oxygen

Regulation (EU) 2018/395

The pilot-in-command shall ensure that:

  1. all crew members engaged in performing duties essential to the safe operation of the balloon use supplemental oxygen continuously whenever he or she determines that, at the altitude of the intended flight, the lack of oxygen might result in impairment of the faculties of crew members; and
  2. supplemental oxygen is available to passengers when lack of oxygen might harmfully affect them.

AMC1 BOP.BAS.180 Use of supplemental oxygen

General

When the pilot-in-command cannot determine how the lack of oxygen might affect all occupants on board, he or she should ensure that:

  1. all flight crew members engaged in performing duties essential to the safe operation of a balloon use supplemental oxygen for any period in excess of 30 minutes when the pressure altitude is between 10 000 and 13 000 ft; and
  2. all occupants use supplemental oxygen for any period when the pressure altitude is above 13000 ft.

BOP.BAS.185 Operational limitations at night

en/bop.bas/180.txt · Last modified: 2024/02/25 06:16 by Volker Löschhorn

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki